Wednesday, November 12, 2008

Red Blood Cells

In this micro-photo of blood cells, platelets are stained purple. A T-Lymphocyte white cell is stained green, and a Monocyte white cell is stained gold. Red blood cells are red.
.
.
.
.

Mitral Valve Prolapse

.

Mitral valve prolapse is a disorder in which, during the contraction phase of the heart, the mitral valve does not close properly. When the valve does not close properly it allows blood to backflow into the left atrium. Some symptoms can include palpitations, chest pain, difficulty breathing after exertion, fatigue, cough, and shortness of breath while lying down.

.

Source of Image:

http://www.web-books.com/eLibrary/Medicine/Neonatal/Images/Marfan.gif


,

,

,

,

Tuesday, November 11, 2008

Holter Monitors


What To Expect When Using a Holter or Event Monitor
.
Your experience while using a Holter or event monitor depends on the type of monitor you have. However, most monitors have some factors in common.
.
Recording the Heart’s Electrical Activity
.
All monitors record the heart’s electrical activity. So, it’s important to maintain a clear signal between the sensors (electrodes) and the recording device.
.
In most cases, the sensors are attached to your chest with sticky patches. Wires connect the sensors to the monitor. You usually can clip the monitor to your belt or carry it in your pocket. (Postevent and implantable loop recorders don’t have chest sensors.)

Holter or Event Monitor
.
Figure A shows how a Holter or event monitor attaches to a patient. In this example, the monitor is clipped to the patient’s belt and electrodes are attached to his chest. Figure B shows an electrocardiogram strip, which maps the data from the Holter or event monitor.
.
A good stick between the patches and your skin helps provide a clear signal. Poor contact leads to a poor recording, which is hard for your doctor to read.
.
Oil, too much sweat, and hair can keep the patches from sticking to your skin. You may need to shave the area where your doctor will attach each patch. You will need to clean the area with a special prep pad that your doctor provides.
.
You may need to use a small amount of special paste or gel to make the patches stick to your skin better. Some patches come with paste or gel on them.
.
Too much movement can pull the patches away from the skin or create “noise” on the rhythm strip. A rhythm strip is a graph showing the pattern of the heartbeat. Noise looks like a lot of jagged lines and makes it hard for the doctor to see the real rhythm of the heart.
.
When you have a symptom, stop what you’re doing. This way you can be sure that the recording shows the heart’s activity rather than your movement.
.
Your doctor will tell you whether you need to adjust your activity level during the testing period. If you exercise, choose a cool location to avoid sweating too much. This will help the patches stay sticky.
.
Other everyday items also can disrupt the signal between the sensors and the monitor. These items include magnets, metal detectors, microwave ovens, and electric blankets, toothbrushes, and razors. Avoid using these items. Also avoid areas with high voltage.
.
Cell phones and iPods may interfere with the signal if they’re too close to the monitor. When using any electronic device, try to keep it at least 6 inches away from the monitor.

Keeping a Diary
.
When using a Holter or event monitor, you need to keep a diary of your symptoms and activities. Write down when symptoms occur, what they are, and what you were doing at the time.
.
The most common symptoms of heart rhythm problems include:
Palpitations. This is the feeling that your heart is pounding, racing, fluttering, or beating unevenly.

Fainting or feeling dizzy.
.
It’s important to note the time symptoms occur, because your doctor matches the data with the information in your diary. This allows your doctor to see whether certain activities trigger changes in your heart rate and rhythm.
.
You also should include details in your diary about when you take any medicine or if you feel stress at certain times during the test.

What To Expect With Specific Monitors
.
Holter Monitor
.
The Holter monitor is about the size of a large deck of cards. You wear it for 24 to 48 hours. When the test is complete, you return the device to your doctor’s office. The results are stored on the device.
.
You can’t get the monitor wet, so you won’t be able to bathe or shower. You can take a sponge bath if needed.
.
The recording period for a standard Holter monitor may be too short to capture a heart rhythm problem. If this is the case, you may need a wireless Holter monitor.

Wireless Holter monitors can record for a longer time than standard Holter monitors. A wireless monitor records for a preset amount of time. It then automatically sends data from the monitor to your doctor’s office.
These monitors are called wireless because they use a cell phone to send the data to your doctor’s office. They still have wires that connect the device to the sensors stuck to your chest.
.
You can use a wireless Holter monitor for days or even weeks until signs or symptoms of a heart rhythm problem occur.
.
The batteries in the wireless monitor must be changed every 1 to 2 days. You will need to detach the sensors to shower or bathe and then reattach them.
.
Event Monitors
.
Event monitors are slightly smaller than Holter monitors. Event monitors record heart rhythm problems when you activate them. They can be worn for weeks or until symptoms occur.
.
Most event monitors are worn like Holter monitors—clipped to a belt or carried in a pocket. When you have symptoms, you simply push a button to start recording.
.
Postevent Recorders
.
Postevent recorders may be worn like a wristwatch or carried in a pocket. The pocket version is about the size of a thick credit card. These recorders don’t have wires that connect the device to chest sensors.
To start the recorder when you feel a symptom, you hold it to your chest. To start the wristwatch version, you touch a button on the side of the watch.
.
You send the stored data to your doctor’s office using a telephone. Your doctor will explain how to use the monitor before you leave the office.

Autodetect Recorders
.
Autodetect recorders are about the size of the palm of your hand. Wires connect the device to sensors on your chest.
.
You don’t need to start an autodetect recorder. This type of monitor
automatically starts recording when it detects an abnormal heart rhythm. It then sends the data to your doctor’s office.
.
Implantable Loop Recorders
.
Implantable loop recorders are about the size of a pack of gum. This type of event monitor is inserted under the skin on your chest. No chest sensors are used.
.
The device records either when you activate it or automatically when symptoms occur. It depends on how your doctor programs it. Devices may differ, so your doctor will tell you how to use it. In some cases, a special card is held close to the recorder to start it.
,
.
..
.

EKG


General Description

As the heart undergoes depolarization and repolarization, the electrical currents that are generated spread not only within the heart, but also throughout the body. This electrical activity generated by the heart can be measured by an array of electrodes placed on the body surface. The recorded tracing is called an electrocardiogram (ECG, or EKG). A "typical" ECG tracing is shown to the right. The different waves that comprise the ECG represent the sequence of depolarization and repolarization of the atria and ventricles. The ECG is recorded at a speed of 25 mm/sec, and the voltages are calibrated so that 1 mV = 10 mm in the vertical direction. Therefore, each small 1-mm square represents 0.04 sec (40 msec) in time and 0.1 mV in voltage. Because the recording speed is standardized, one can calculate the heart rate from the intervals between different waves.
.
P wave
.
The P wave represents the wave of depolarization that spreads from the SA node throughout the atria, and is usually 0.08 to 0.1 seconds (80-100 ms) in duration. The brief isoelectric (zero voltage) period after the P wave represents the time in which the impulse is traveling within the AV node (where the conduction velocity is greatly retarded) and the bundle of His. Atrial rate can be calculated by determining the time interval between P waves. Click here to see how atrial rate is calculated.
.
The period of time from the onset of the P wave to the beginning of the QRS complex is termed the P-R interval, which normally ranges from 0.12 to 0.20 seconds in duration. This interval represents the time between the onset of atrial depolarization and the onset of ventricular depolarization. If the P-R interval is >0.2 sec, there is an
AV conduction block, which is also termed a first-degree heart block if the impulse is still able to be conducted into the ventricles.
.
QRS complex
.
The QRS complex represents ventricular depolarization. Ventricular rate can be calculated by determining the time interval between QRS complexes.
Click here to see how ventricular rate is calculated.
The duration of the QRS complex is normally 0.06 to 0.1 seconds. This relatively short duration indicates that
ventricular depolarization normally occurs very rapidly. If the QRS complex is prolonged (> 0.1 sec), conduction is impaired within the ventricles. This can occur with bundle branch blocks or whenever a ventricular foci (abnormal pacemaker site) becomes the pacemaker driving the ventricle. Such an ectopic foci nearly always results in impulses being conducted over slower pathways within the heart, thereby increasing the time for depolarization and the duration of the QRS complex.
.
The shape of the QRS complex in the above figure is idealized. In fact, the shape changes depending on which
recording electrodes are being used. The shape will also change when there is abnormal conduction of electrical impulses within the ventricles. The figure to the right summarizes the nomenclature used to define the different components of the QRS complex.
.
ST segment

The isoelectric period (ST segment) following the QRS is the time at which the entire ventricle is depolarized and roughly corresponds to the
plateau phase of the ventricular action potential. The ST segment is important in the diagnosis of ventricular ischemia or hypoxia because under those conditions, the ST segment can become either depressed or elevated.
.
T wave
.
The T wave represents
ventricular repolarization and is longer in duration than depolarization (i.e., conduction of the repolarization wave is slower than the wave of depolarization). Sometimes a small positive U wave may be seen following the T wave (not shown in figure at top of page). This wave represents the last remnants of ventricular repolarization. Inverted or prominent U waves indicates underlying pathology or conditions affecting repolarization.
.
Q-T interval
.
The Q-T interval represents the time for both ventricular depolarization and repolarization to occur, and therefore roughly estimates the duration of an average ventricular action potential. This interval can range from 0.2 to 0.4 seconds depending upon heart rate. At high heart rates, ventricular action potentials shorten in duration, which decreases the Q-T interval. Because prolonged Q-T intervals can be diagnostic for susceptibility to certain types of tachyarrhythmias, it is important to determine if a given Q-T interval is excessively long. In practice, the Q-T interval is expressed as a "corrected Q-T (QTc)" by taking the Q-T interval and dividing it by the square root of the R-R interval (interval between ventricular depolarizations). This allows an assessment of the Q-T interval that is independent of heart rate. Normal corrected Q-Tc intervals are less than 0.44 seconds.
.
There is no distinctly visible wave representing atrial repolarization in the ECG because it occurs during ventricular depolarization. Because the wave of atrial repolarization is relatively small in amplitude (i.e., has low voltage), it is masked by the much larger ventricular-generated QRS complex.
.
ECG tracings recorded simultaneous from different electrodes placed on the body produce different characteristic waveforms.
As the heart undergoes depolarization and repolarization, electrical currents spread throughout the body because the body acts as a volume conductor. The electrical currents generated by the heart are commonly measured by an array of electrodes placed on the body surface and the resulting tracing is called an electrocardiogram (ECG, or EKG). By convention, electrodes are placed on each arm and leg, and six electrodes are placed at defined locations on the chest. These electrode leads are connected to a device that measures potential differences between selected electrodes to produce the characteristic ECG tracings.
Some of the ECG leads are bipolar leads (e.g., standard limb leads) that utilize a single positive and a single negative electrode between which electrical potentials are measured. Unipolar leads (augmented leads and chest leads) have a single positive recording electrode and utilize a combination of the other electrodes to serve as a composite negative electrode. Normally, when an ECG is recorded, all leads are recorded simultaneously, giving rise to what is called a 12-lead ECG.

Boston Scientific Pacemaker


Wednesday, May 7, 2008


Boston Scientific ALTREA Pacemaker EU Approved

ALTRUA is Boston Scientific's most advanced pacemaker and delivers enhanced therapies while maintaining its small size and battery longevity. It is the first Boston Scientific-branded pacemaker to treat bradycardia, a condition in which the heart beats too slowly -- usually less than 60 beats per minute -- depriving the body of sufficient oxygen.
.
Multiple Atrial Ventricular (AV) Delay programming options: These options are designed to reduce unnecessary right ventricular (RV) pacing, without dropping ventricular beats, a key distinction from other competitive RV pacing algorithms. The ALTRUA 50 and 60 series also include an enhanced AV search hysteresis feature, now with an extendable AV delay out to 400 milliseconds, providing physicians with additional flexibility to tailor device programming for unique patient needs.
.
Minute Ventilation (MV) Blended Sensor: This proprietary technology treats a condition called Chronotropic Incompetence, which is the inability of the heart to regulate its rate appropriately in response to physical activity and emotional stress. Boston Scientific's MV Blended sensor is the only sensor that has been shown to restore Chronotropic Competence.
.
Ventricular Rate Regulation (VRR): This feature helps physicians manage patients with frequent atrial arrythmias.
.
Automatic Capture: This capability is designed to offer automatic, safe and accurate ventricular pulse management. The device checks every heart beat to see if the lower chambers of the heart contract in response to the delivered pulse. If no contraction is detected, a backup pace with more energy is delivered.


Pacemaker


A pacemaker is a small, battery-operated electronic device which is inserted under the skin to help the heart beat regularly and at an appropriate rate. The pacemaker has leads that travel through a large vein to the heart, where the wires are anchored. The leads send the electrical impulses to the heart to tell it to beat.
.
.
.

Coronary Bypass Surgery


CORONARY ARTERY BYPASS SURGERY
.
The coronary artery bypass graft (CABG) is the gold-standard surgical treatment for coronary artery disease (CAD). This procedure is done if angioplasty proves to be unsuccessful and the physician is unable to place stents to open up the narrowed artery. CABG’s have been performed for nearly 30 years.
.

During a CABG the sternum is separated and the ribs are spread apart to allow access to the heart. Often blood circulation and breathing functions will be taken over by a heart-lung machine. This surgery though, is now being done more frequently in a manner called off-pump where the heart-lung machine is not used. The surgeon uses a piece of vein or artery to form a bypass to enable blood to flow around the area of blockage. The goal of this surgery is not to repair the area of blockage but to detour the flow of blood around the area.
.

Various vessels can be accessed and used for this grafting procedure. The most common vessel that has been used in the past is the saphenous vein from the leg. But the radial artery from the arm is now more commonly be accessed and used for the procedure. As long as the patient has adequate blood flow to the lower arm via the ulnar artery the use of the radial artery poses no problem for blood flow through the patients arm. Another artery that is sometimes used is the internal mammary artery from the chest.
.
Occasionally an artery from the stomach (gastroepiploid artery) also may be used as bypass grafts.
.

Depending on which blood vessel is used, one end is either sewn to the aorta or may remain connected to the larger artery where it originated. The other end is grafted beyond the area of blockage in a specific coronary artery.
.

The day and night before surgery the patient is usually in the hospital. Usually a chest x-ray will be required prior to surgery. Usually blood is drawn to Type and Screen the patient’s blood in case they require blood transfusion during or after the surgery. Other tests are also routinely done such as a CBC, tests on the patient’s electrolytes, and coagulation studies such as a PT/PTT/INR, liver function tests, EKG, and a urinalysis. Often the evening before surgery the patient’s chest and legs are scrubbed with a bacterial-killing solution ordered by the surgeon. Also before surgery the chest and legs will be shaved.
.

The patient should always be NPO after midnight the night before surgery which means that the patient should have nothing to eat or drink. Often the patient is put on a maintenance IV fluid drip during this time so that the patient does not become dehydrated.On the day of surgery, before the actual surgery is done, often a Swan-ganz catheter is inserted in order to measure heart function during the surgery. Obviously the patient will be intubated prior to the surgery and given anesthesia during surgery.
During surgery functions of the heart, including blood flow and oxygenation, are rerouted through a heart-lung machine. While the heart-lung machine is taking care of the functions of the heart, the heartbeat can be stopped by administering what is called a cardioplegic solution. Cardioplegic solutions protect and preserve the myocardium for extended time periods during open heart surgery and reperfusion by preventing ischemia. Usually the heart remains stopped for 30 to 90 minutes during the usual 4-5 hour surgery.
.

The vessels that are going to be used for the bypass graft are removed before the patient is put on the heart-lung machine. After the grafting is completed and blood is flowing adequately around the blocked artery, the patient is taken off of the heart-lung machine. After the surgery is over the sternum is usually closed with wire and the surface area is closed with staples. Most of the time there are wires coming from the chest, usually atrial and ventricular, in order to be able to use a pacemaker in the event that the electrical activity of the heart is not adequate.
.

After the surgery is completed the patient is usually transferred from the operating room to the cardiac intensive care unit where they are closely monitored by skilled cardiac intensive care unit nurses. These patients generally have chest tubes, due to the chest being opened; they are often are intravenous medications that are being administered in a drip to control blood pressure, heart rate, cardiac output, and other hemodynamic parameters. The patient remains intubated until the physician is confident that the patient can adequately breathe on their own. Patients though are extubated much more quickly now than they were a few years ago. There is a strong belief that the sooner the patient is up and about the faster they will recover. The nurse taking care of these patients must be very skilled and educated regarding the medications, chest tubes, monitoring of blood loss from chest tubes, Swan-ganz catheters, and respiratory care of these patients.
.

There are complications that can arise from coronary artery bypass surgery. These include difficulty breathing, bleeding ( blood loss from the chest tubes need to be carefully monitored ), infection, hypertension, and arrhythmias, particularly atrial fibrillation. Most of these complications are short-term and are not life-threatening. More serious complications that may arise, usually from the use of the heart-lung machine, include kidney failure, heart attack, stroke, or even death. These risks are obviously higher in patients with diabetes, older patients, and patients with other major health problems
.

Usually the patient needs to make some lifestyle changes after surgery. These include eating a healthy diet, quitting smoking, monitoring blood pressure, monitoring diabetes closely if they have that condition, be compliant with taking medications, and take part in regular exercise, generally begun during a cardiac rehabilitation program.
.

A very important part of the patient’s recovery from coronary artery bypass surgery is patient education usually done by nursing personnel. Lifestyle changes need to be reinforced. Education regarding medications that the patient will be taking is important as it has been shown that patients that understand what medications they are taking, and the reason for taking them, are more compliant with taking these medications.

Monday, November 10, 2008

Restenosis

http://www.nhlbi.nih.gov/health/dci/images/stent_restenosis.gif


What Are the Risks of Having a Stent?
.
Risks Related to Angioplasty
.
Any medical procedure has risks, but major complications from angioplasty are rare. The most common risks from angioplasty include:
.
Bleeding from the site where the catheter was inserted into the skin
Damage to the blood vessel from the catheter
Infection
Allergic reaction to the dye used during the procedure
.
Another common problem after angioplasty is too much tissue growth within the treated portion of the artery. This can cause the artery to narrow or close again, which is called restenosis. This problem is often avoided with the use of newer stents coated with medicines that help prevent too much tissue growth. Treating the tissue around the stent with radiation also can prevent tissue growth. For this procedure, the doctor puts a wire through a catheter to where the stent is placed. The wire releases radiation and stops cells around the stent from growing and blocking the artery.
.
.
.
.

Coronary Stent


A Coronary Stent is a small wire mesh tube that is used to help keep coronary (heart) arteries open after angioplasty. A catheter with an empty balloon on its tip is guided into the narrowed part of the artery. The balloon is then filled with air to flatten the plaque against the artery wall. Once the artery is open, a second balloon catheter with a stent on its tip is inserted into the artery and inflated, locking the stent into place. .

Sunday, November 9, 2008

Stent

http://www.usatoday.com/news/health/2006-12-05-stent-warning_x.htm
.
.
Stent: A tube designed to be inserted into a vessel or passageway to keep it open.

.
Stents are inserted into narrowed coronary arteries to help keep them open after balloon angioplasty. The stent then allows the normal flow of blood and oxygen to the heart.

Stents placed in narrowed carotid arteries (the vessels in the front of the neck that supply blood to the brain) appear useful in treating patients at elevated risk for stroke.

Stents are also used in other structures such as the esophagus to treat a constriction, the ureters to maintain the drainage of urine from the kidneys, and the bile ductbile to keep it open.
.
Named after Charles R. Stent (1845-1901), an English dentist.

.
.
.

Even more aorta



The aorta is usually divided into seven segments/sections:
.
Ascending aorta — the section between the heart and the arch of aorta
.
Arch of aorta —the peak part that looks somewhat like an inverted "U"
.
Descending aorta —the section from the arch of aorta to the point where it divides into the common iliac arteries.
.
Thoracic aorta —the half of the descending aorta above the diaphragm.
..
Abdominal aorta —the half of the descending aorta below the diaphragm.
.

More aorta

Kidneys and the Aorta


.
The aorta is the largest artery in the human body, originating from the left ventricle of the heart and bringing oxygenated blood to all parts of the body in the systematic circulation.
.
.
.
.